空气载能辐射末端应用试验研究
[Abstract]:With the development of the times, the technology of air conditioning terminal system has been very mature, but the end system of airborne energy radiation is rarely known. The air borne radiation air conditioning terminal technology inherits the characteristics of low energy consumption, high comfort and low noise of the traditional radiation end system, and solves the problems of complex construction, high maintenance difficulty and easy condensation of the traditional radiation end system. The thermal comfort problem of the air energy carrying radiation air conditioning terminal system is a key part in the design of the air energy carrying radiation air conditioning system, and it can also be used as a basis for the selection of the equipment. The study of energy saving based on the thermal comfort can not only meet the requirements of the thermal comfort. Also can obtain energy consumption saving to the greatest extent. In addition, the heating problem in the area of cold winter and hot summer is studied separately, which provides the experimental basis for the end system of air energy transfer radiation to be one of the choices of heat supply in winter in the area of cold winter and hot summer. In this paper, the air energy carrying radiation air conditioning system in an office of Hongye Building, Hunan University, is tested on the spot, which provides a great deal of valuable measured data for the thermal comfort and energy saving of the air energy carrying radiation air conditioning system. In addition, the study on the heating of the air energy carrying radiation air conditioning system in a drug control institute in Changde provides data and analysis methods for solving the heating problems in the cold and hot areas in winter and summer. The specific work and conclusions of this paper are as follows: (1) the air temperature, air relative humidity, air velocity, average radiation temperature, thermal resistance and metabolism of human body were measured and calculated. The thermal comfort evaluation index PMV and PPD, proposed by Professor Fanger are used to obtain the temperature range to meet the requirements of human thermal comfort. The results are compared with the real person comprehensive investigation and verify the reliability of the obtained results. The results show that under the same thermal comfort requirement, the air energy carrying radiation terminal system has a better energy saving effect than that of the common air conditioning terminal system. The maximum energy saving rate measured by the experiment can be as high as 26.4um. (2) by measuring the roof temperature, wall temperature, floor temperature and indoor air temperature of a certain balance chamber of Changde Drug Control Institute, Combined with the heat flux of each test point and the wind speed of the inside roof and the return air, the test data and the test time are made into chart form, so that the reasonable analysis can be made. The results show that the peak value of roof temperature in the air supply area is more synchronous with that in the return air area, and there is no obvious phase difference. Through the radiant heat transfer between the roof and the ground, the temperature of the ground can be raised effectively, and the temperature of the wall can be kept high, and under different heating conditions, the ground temperature is higher than the average predicted temperature of indoor air, which indicates that in the process of heating in winter, The ground closer to the human body has a more comfortable temperature. All of the above can provide reliable basis for the selection of air energy carrying radiation terminal system as one of the winter heating options in cold winter and hot summer areas.
【学位授予单位】:湖南大学
【学位级别】:硕士
【学位授予年份】:2015
【分类号】:TU831
【相似文献】
相关期刊论文 前10条
1 张洪弟;汪学骞;;服装及纺织品湿热舒适性的灰色关联分析[J];山东纺织工学院学报;1991年01期
2 贾庆贤,赵荣义;风速频谱对人体热舒适性的影响[J];清华大学学报(自然科学版);2001年06期
3 杜强;;基于热舒适性的室内环境控制分析[J];河北能源职业技术学院学报;2008年01期
4 曹彬;朱颖心;欧阳沁;周翔;黄莉;;北京地区冬季室内人体热舒适性及热适应性调查[J];暖通空调;2010年05期
5 周成梅;朱庭浩;;某空调办公室夏季热舒适性分析[J];科技信息;2010年25期
6 张吉礼;马良栋;赵天怡;;建筑环境热舒适性研究进展与趋势分析[J];建筑热能通风空调;2011年01期
7 黄俊;顾洁;王晓博;;多孔太阳墙式太阳能房间与普通房间热舒适性分析[J];节能;2012年02期
8 郑立星;卢苇;陈洪杰;冯冰凌;;基于空调使用行为的南宁地区夏季室内热舒适性研究[J];四川建筑科学研究;2012年06期
9 王汉青;康良麒;李端茹;杨荣郭;;某办公室夏季热舒适性数值模拟与实测分析[J];建筑热能通风空调;2013年01期
10 宁勇飞;谢吉平;李惠敏;;内廊式建筑南北房间热舒适性评价[J];建筑热能通风空调;2013年06期
相关会议论文 前10条
1 诸明杰;;用动态情况分析商场冬季热舒适性空调参数[A];全国暖通空调制冷1998年学术年会论文集(2)[C];1998年
2 李艳菊;刘俊杰;;某中学教室室内空气污染及热舒适性研究[A];全国暖通空调制冷2006学术年会资料集[C];2006年
3 茅靳丰;毛维;付建明;范良凯;;地下工程内空调布置方式对热舒适性的影响[A];全国暖通空调制冷2004年学术年会资料摘要集(1)[C];2004年
4 王季楼;卞康;;高大空间分层空调建立条件及热舒适性的若干因素分析[A];全国暖通空调制冷2008年学术年会论文集[C];2008年
5 王威;狄洪发;;新型辐射吊顶供暖的实验研究与热舒适性讨论[A];全国暖通空调制冷2002年学术年会论文集[C];2002年
6 赵立华;张泓森;;辐射板采暖房间热舒适性影响因素分析[A];全国暖通空调制冷2004年学术年会资料摘要集(2)[C];2004年
7 陶培德;;人体对环境热适性反应的差异[A];全国暖通空调制冷1990年学术年会论文集(下)[C];1990年
8 杨静竹;雷波;;火车站热舒适性调查与分析研究[A];第十四届西南地区暖通空调热能动力学术年会论文集[C];2011年
9 郭利华;朱能;蒋薇;;人体热舒适性的实验研究[A];全国暖通空调制冷2002年学术文集[C];2002年
10 许树文;王炜;陈菊芳;;加强基础研究,提高国产西服的热舒适性[A];2006年全国服装科技创新与发展论坛论文集[C];2006年
相关重要报纸文章 前4条
1 李成伟;空气的温度、湿度、焓值与热舒适性[N];中国建设报;2013年
2 李成伟;空气的温度、湿度、焓值与热舒适性[N];中国建设报;2013年
3 薛世山;三能态低碳集成卫浴房[N];中国建设报;2013年
4 本报记者 薛秀春;沐浴新时代 节能新奉献[N];中国建设报;2013年
相关博士学位论文 前5条
1 王润泽;高危生物污染环境下主动净化送风式正压生物防护服的使用安全性与热舒适性研究[D];中国人民解放军军事医学科学院;2016年
2 端木琳;桌面工位空调系统室内热环境与热舒适性研究[D];大连理工大学;2007年
3 向立平;空调客车内气流分布特性及动态热舒适性研究[D];中南大学;2011年
4 郭春梅;天津地区办公建筑自然通风热舒适性研究[D];天津大学;2010年
5 张文灿;汽车乘坐空间热环境与乘员热舒适性分析关键技术研究[D];华南理工大学;2013年
相关硕士学位论文 前10条
1 王鑫;基于胶原纤维微观三维构象的皮革服装湿热舒适性研究[D];陕西科技大学;2015年
2 张亚峰;高温干燥地区开放式站台空调状态下热环境评价与改善[D];西南交通大学;2014年
3 李武刚;冬季高校教室热舒适性控制方法研究[D];西安建筑科技大学;2015年
4 张盟;渗透式FADS控制的环境流场和温度场数值模拟及热舒适性预测[D];浙江理工大学;2016年
5 赵林林;基于人体热舒适性的汽车空调除霜性能研究[D];上海工程技术大学;2016年
6 何良;车室内流场和温度场的数值模拟与研究[D];上海工程技术大学;2016年
7 陈城;夏热冬暖地区综合商场功能区冬季热舒适性研究[D];华南理工大学;2016年
8 公丕健;客机地面作业中客舱温湿度适宜性范围研究[D];中国民航大学;2016年
9 吴凡昊;空气载能辐射末端应用试验研究[D];湖南大学;2015年
10 俞准;暂留区热舒适性参数研究[D];华北电力大学(河北);2004年
,本文编号:2421306