【摘要】:针对中国特高压输电工程中1 100 kV高压断路器开合并联电抗器的试验需求,并结合国家电网公司提出的高于标准要求的试验参数,设计与开发了一种双端加压的试验回路。进一步应用PSCAD/EMTDC仿真软件对所设计的试验回路进行仿真计算,仿真结果表明,试验回路能够满足试验参数的需求,并在西安高压电器研究院有限责任公司大容量检测室进行了1 100 kV高压断路器开合并联电抗器的型式试验。最后,分析和讨论了正常开断、单次复燃开断、多次复燃开断3种典型的试验结果。
[Abstract]:According to the test demand of the parallel reactor of 1 100 kV high voltage circuit breaker in China UHV transmission project and the test parameters higher than the standard required by State Grid Company, a double end pressurized test circuit is designed and developed.The PSCAD/EMTDC simulation software is used to simulate the designed test circuit. The simulation results show that the test loop can meet the requirements of the test parameters.The type test of the parallel reactor of 1 100 kV high voltage circuit breaker was carried out in the large capacity test room of Xi'an High Voltage Electrical Research Institute Co., Ltd.At last, three typical test results are analyzed and discussed, which are normal breaking, single reburning and multiple reburning.
【作者单位】: 西安高压电器研究院有限责任公司;国网临沂供电公司;