基于泄漏电流特性的交流悬式绝缘子覆冰闪络特性
发布时间:2018-08-14 17:03
【摘要】:为了揭示覆冰闪络特性以提高闪络预测结果的准确性,对比分析了长串和短串覆冰绝缘子交流闪络过程的泄漏电流特性。根据泄漏电流时域波形将绝缘子覆冰闪络过程分为4个阶段,选取第3阶段的准恒定特征电流(IW)和第4阶段闪络前最后一周期泄漏电流峰值(IFT)作为闪络预测的2个重要特征量,并研究了其与覆冰严重程度、污秽度和覆冰水电导率的关系。结果表明:IW和IFT随覆冰水电导率的增加近似线性增大,但几乎不受污秽度影响;2者随覆冰严重程度的增加而增大,当伞裙间隙被冰棱完全桥接时达到饱和值;IW可以用于覆冰闪络的早期预警,而IFT可作为临界闪络判据。
[Abstract]:In order to reveal the characteristics of icing flashover to improve the accuracy of flashover prediction, the leakage current characteristics of long and short series ice insulators during AC flashover were compared and analyzed. According to the time domain waveform of leakage current, the insulator icing flashover process is divided into four stages. The quasi-constant characteristic current (IW) of the third stage and the peak leakage current peak value (IFT) of the last cycle before the fourth stage flashover are selected as two important characteristics for the flashover prediction. The relationship between the degree of ice coating, pollution and conductivity of iced water was studied. The results show that the IFT and the IW increase linearly with the increase of the conductivity of ice-covered water, but increase with the increase of the degree of icing severity. When the gap of umbrella skirt is completely bridged by ice edge, the saturation value of IW can be used for early warning of ice flashover, and IFT can be used as critical flashover criterion.
【作者单位】: 西安交通大学电气工程学院;中国电力科学研究院;国网天津市电力公司城南供电分公司;
【基金】:国家电网公司科技项目(GY71-13-034)~~
【分类号】:TM216
本文编号:2183525
[Abstract]:In order to reveal the characteristics of icing flashover to improve the accuracy of flashover prediction, the leakage current characteristics of long and short series ice insulators during AC flashover were compared and analyzed. According to the time domain waveform of leakage current, the insulator icing flashover process is divided into four stages. The quasi-constant characteristic current (IW) of the third stage and the peak leakage current peak value (IFT) of the last cycle before the fourth stage flashover are selected as two important characteristics for the flashover prediction. The relationship between the degree of ice coating, pollution and conductivity of iced water was studied. The results show that the IFT and the IW increase linearly with the increase of the conductivity of ice-covered water, but increase with the increase of the degree of icing severity. When the gap of umbrella skirt is completely bridged by ice edge, the saturation value of IW can be used for early warning of ice flashover, and IFT can be used as critical flashover criterion.
【作者单位】: 西安交通大学电气工程学院;中国电力科学研究院;国网天津市电力公司城南供电分公司;
【基金】:国家电网公司科技项目(GY71-13-034)~~
【分类号】:TM216
【相似文献】
相关期刊论文 前10条
1 孙羽;王秀丽;王建学;王锡凡;;架空线路覆冰闪络跳闸特性分析与风险建模[J];中国电机工程学报;2011年31期
2 孙羽;王秀丽;;冰灾天气下输电网覆冰闪络跳闸风险评估[J];东北电力技术;2013年09期
3 李鹏;范建斌;李武峰;宿志一;;高压直流输电线路的覆冰闪络特性[J];电网技术;2006年17期
4 粟福珩;贾逸梅;;高压输电线路绝缘子的覆冰闪络与防护[J];水利电力科技;1994年04期
5 孙羽;王秀丽;王建学;王锡凡;吴雄;谢绍宇;;地区电网覆冰闪络跳闸脆弱性曲线及其应用[J];中国电机工程学报;2012年22期
6 舒扬;;输电线路覆冰闪络原因分析与解决方法探讨[J];科技资讯;2012年03期
7 向泽;蒋兴良;张志劲;胡琴;董冰冰;王尧玄;;复合与瓷和玻璃绝缘子直流覆冰闪络特性比较[J];高电压技术;2014年02期
8 武利会;;XZP/XZWP4-160直流绝缘子覆冰闪络电弧特性的研究[J];中国电力;2006年08期
9 王琨;谷永刚;彭青宁;谭敏戈;许阳;;山区超高压输电线路玻璃绝缘子串防覆冰闪络措施研究[J];电网与清洁能源;2008年08期
10 黄振强;;输电线路覆冰闪络事故分析与对策[J];电力安全技术;2010年12期
相关硕士学位论文 前1条
1 刘景姝;直流绝缘子的覆冰闪络特性研究[D];合肥工业大学;2010年
,本文编号:2183525
本文链接:https://www.wllwen.com/kejilunwen/dianlidianqilunwen/2183525.html