当前位置:主页 > 科技论文 > 计算机论文 >

联通IDC机房配电保护控制系统规划设计

发布时间:2018-01-02 20:05

  本文关键词:联通IDC机房配电保护控制系统规划设计 出处:《南昌大学》2014年硕士论文 论文类型:学位论文


  更多相关文章: IDC机房 配电保护 系统规划设计


【摘要】:]DC是互联网数据中心Internet Data Center的简称,它是基于因特网,专为集中加工处理、接收、发送和存贮数据的相关计算机与通信设备提供维护运行的设施场所,并为之提供相关的服务 [1]。IDC机房中的设备种类较多,包括各种动力设备、空调系统、安保系统、网络通信设备、大容量存储设备及大、中型服务器等。为保障各种设备及IDC服务器的正常运行、防止存储数据丢失,对IDC机房电源进行保护及不间断供电就显得尤为重要。目前国内外普遍的做法是采用以交流市电供电为主,加上相应的后备电源构成整个的电源系统。后备电源系统主要有以下几种方式:UPS电源技术、高压直流供电技术、热插拔模块化UPS技术、锂离子蓄电池技术等[2] 本文设计规划的联通IDC机房配电保护控制系统,采用基于ARM7TDMI版本的嵌入式处理器LPC2119为核心,结合可靠的检测与控制电路,实现对IDC机房主市电、备用市电及交流发电机组的快速自投,同时具备三相380V和单相220V交流电源的过流保护、过压保护、欠压保护、漏电保护,以及三相380V交流输入电源的缺相保护等功能。经过投入联通IDC机房一段时期的运行情况来看,本系统可以较好地解决市电供电系统的断电、电流浪涌、频率突变、电压突变、电压纹波、频率漂移、电压突降、脉冲干扰以及外界雷击尖锋等问题,从而保障IDC机房中设备的正常运行。同时配合UPS电源技术,可有效防止存储数据的丢失,维持IDC服务的正常运行。 本系统不仅有效保障机房值守人员的人身安全和设备安全,也为IDC机房不间断网络通信服务提供支撑,因此带来巨大的经济效益。
[Abstract]:DC is the abbreviation of Internet Data Center, an Internet data center, which is based on the Internet and is designed for centralized processing and reception. Computers and communications equipment that transmit and store data provide facilities and services for maintenance and operation. [IDC has a wide range of equipment, including a variety of power equipment, air conditioning systems, security systems, network communications equipment, high-capacity storage equipment and large. Medium servers. To ensure the normal operation of various devices and IDC servers, to prevent the loss of storage data. It is particularly important to protect the power supply and uninterruptible power supply to the IDC engine room. At present, the common practice at home and abroad is to use AC power supply as the main method. The backup power supply system mainly includes the following ways: UPS power technology, HVDC power supply technology, hot-plug modular UPS technology. Lithium ion battery technology. [2] The distribution protection control system of Unicom IDC room is designed in this paper. The embedded processor LPC2119 based on ARM7TDMI version is used as the core, and the reliable detection and control circuit is combined. The main power supply, standby power supply and AC generator set in the IDC engine room can be switched on automatically. At the same time, the over-current protection, over-voltage protection and under-voltage protection of the three-phase 380V and single-phase 220V AC power supply can be realized. Leakage protection, as well as three-phase 380V AC input power supply phase protection and other functions. After putting into the IDC room for a period of time operation. The system can solve the problems of power failure, current surge, frequency mutation, voltage mutation, voltage ripple, frequency drift, voltage sudden drop, pulse interference and external lightning spike. In order to ensure the normal operation of the equipment in the IDC room and with the UPS power technology, it can effectively prevent the loss of stored data and maintain the normal operation of the IDC service. This system not only effectively guarantees the personal safety and equipment safety of the personnel on duty in the computer room, but also provides the support for the uninterrupted network communication service of the IDC computer room, which brings enormous economic benefits.
【学位授予单位】:南昌大学
【学位级别】:硕士
【学位授予年份】:2014
【分类号】:TP308;TM76

【参考文献】

相关期刊论文 前10条

1 吕小妹;;UPS电源在综合自动化保护装置系统中的使用及维护[J];科技创新与生产力;2013年08期

2 郝昱宇;赵天鹏;田俊峰;谢安利;;一种新型智能三相电网缺相保护器的研制[J];价值工程;2013年16期

3 王振军;;室内供配电线路用电设备及配电线路的保护[J];科技与企业;2013年11期

4 杨鹏;;当前直流屏的应用现状及发展趋势分析[J];科技资讯;2013年06期

5 刘化召;陈学锋;俞前;;融合IDC运营支撑系统设计与分析[J];电信科学;2013年01期

6 赵欣悦;张弘强;;对UPS的使用及简介[J];科技致富向导;2012年35期

7 宋湘萍;;推进北京联通IDC增值业务的构想[J];科技资讯;2012年06期

8 尹亚军;王志强;;电压检测型地面电气设备漏电保护技术改造[J];煤矿机电;2012年01期

9 张青松;;广播电视系统中UPS电源的选型与配置[J];现代电视技术;2011年11期

10 陈晓琴;;一种新型的低成本高性能在线式UPS[J];电子技术应用;2011年11期



本文编号:1370712

资料下载
论文发表

本文链接:https://www.wllwen.com/kejilunwen/jisuanjikexuelunwen/1370712.html


Copyright(c)文论论文网All Rights Reserved | 网站地图 |

版权申明:资料由用户87cad***提供,本站仅收录摘要或目录,作者需要删除请E-mail邮箱bigeng88@qq.com