敦煌莫高窟微环境控制方式的CFD仿真与实验
发布时间:2018-01-29 04:15
本文关键词: 计算流体力学 主动抽风 主动送风 出处:《敦煌研究》2017年06期 论文类型:期刊论文
【摘要】:为了确保对洞窟的控制方式和控制量不会对壁画和塑像有任何程度的损害,采用计算流体力学CFD技术对洞窟微环境引入的控制手段进行分析,结果表明主动抽风产生的气压以及壁画表面的风速都比主动送风方式要小。在对第131窟所做的空气交换率实验证实了CFD的分析结果。因此主动抽风控制方式在中小洞窟对于减小空气湿度以及降低二氧化碳浓度都具有良好的作用,同时对洞窟内的文物影响很小。
[Abstract]:In order to ensure that the control mode and control quantity of the cave will not damage the murals and statues to any extent, the CFD technology of computational fluid dynamics is used to analyze the control means introduced into the cave micro-environment. The results show that the air pressure generated by active ventilation and the wind speed on the surface of fresco are smaller than those on the surface of the mural. The air exchange rate experiment on the 131th Grottoes confirms the analytical results of CFD. The method has a good effect on reducing air humidity and carbon dioxide concentration in small and medium-sized caves. At the same time, it has little influence on the cultural relics in the caves.
【作者单位】: 机械工业仪器仪表综合技术经济研究所网络控制研究中心;敦煌研究院保护研究所;
【分类号】:K879.21
【正文快照】: 引言世界著名遗产地敦煌莫高窟地处戈壁腹地,是我国第一批列入世界遗产名录的文化遗产。敦煌莫高窟文化瑰宝的保护一直得到我国政府的高度重视。阴雨天气和沙尘天气导致洞窟微环境突变,对洞窟壁画的保存带来很大的负面影响[1][2]。阴雨天,外界环境空气是高湿度,随着洞窟内外空