多b值弥散加权成像与动脉自旋标记评估轻度认知功能障碍海马灌注的对比研究
发布时间:2018-04-13 17:01
本文选题:认知障碍 + 磁共振成像 ; 参考:《中国临床医学影像杂志》2017年08期
【摘要】:目的 :对比分析多b值弥散加权成像(MB-DWI)与动脉自旋标记(ASL)在评价轻度认知功能障碍(MCI)患者海马灌注异常中的临床应用价值。方法:依据诊断标准与排除标准,选择MCI患者(MCI组)和认知功能正常的老年人(NC组)各20例,进行常规MRI平扫、MRA、ASL以及MB-DWI扫描,根据ASL-CBF图测量双侧海马最大rCBF_(ASL)值,并测量相应区域MBDWI与灌注相关参数fast ADC-mono、fraction of fast ADC-mono、fast ADC-bi、fraction of fast ADC-bi值,对MCI组和NC组分别进行相应参数的组间统计学差异分析和Pearson相关性分析。结果:MCI组双侧海马rCBF_(ASL)值较NC组降低(P0.05);MCI组双侧海马fast ADC-mono、fraction of fast ADC-mono、fraction of fast ADC-bi值与NC组的比较差异有统计学意义(P0.05),双侧海马fast ADC-bi值较NC组减低,差异无统计学意义(P0.05);除fast ADC-bi值外,MCI组fast ADC-mono、fraction of fast ADC-mono、fraction of fast ADC-bi值与r CBFASL的相关性具有统计学意义(P0.05)。结论:MB-DWI和ASL在检出MCI患者海马的灌注改变方面具有一致性,可用于评估MCI患者灌注改变,有利于指导临床。
[Abstract]:Objective: to compare and analyze the clinical value of MB-DWI and ASL in evaluating hippocampal perfusion abnormalities in patients with mild cognitive impairment (MCI).Methods: according to the diagnostic criteria and exclusion criteria, 20 MCI patients with MCI) and 20 elderly patients with normal cognitive function (NC group) were examined by conventional MRI plain scan and MB-DWI scanning. The maximum rCBFStax ASL value of bilateral hippocampus was measured according to ASL-CBF images.The corresponding regional MBDWI and perfusion related parameters fast ADC-monofraction of fast ADC-Monodo fast ADC-ADC-Monodo fractionof fast ADC-bi were measured. The statistical difference analysis and Pearson correlation analysis of the corresponding parameters between MCI group and NC group were carried out.Results compared with NC group, the value of fast ADC-bi in bilateral hippocampus of MCI group was significantly lower than that in NC group (P 0.05), and the value of fast ADC-bi in bilateral hippocampus was lower than that in NC group (P 0.05).There was no significant difference (P 0.05), except for fast ADC-bi, the correlation between the value of fast ADC-monochrome fractionation of fast ADC-monotaxa fractionation of fast ADC-bi and r CBFASL was statistically significant (P 0.05).ConclusionTwo MB-DWI and ASL are consistent in detecting the changes of hippocampal perfusion in patients with MCI, which can be used to evaluate the changes of perfusion in MCI patients and to guide clinical practice.
【作者单位】: 泰山医学院;山东大学附属千佛山医院影像科;
【基金】:山东省科技发展计划项目(2009GG10002024) 山东省医药卫生科技发展计划项目(2009HW075)
【分类号】:R445.2;R749.1
【相似文献】
相关期刊论文 前10条
1 罗海龙;黄力;;动脉自旋标记的新进展及其在缺血性脑血管病的应用[J];国际医学放射学杂志;2014年01期
2 倪萍;张英魁;史凯宁;赵希刚;王小燕;吴博;陈自谦;;全脑3D动脉自旋标记成像及其在颅内肿瘤病变中的应用[J];中国医疗设备;2013年10期
3 霍英松;周海燕;;动脉自旋标记在小儿中枢神经系统检查中的应用[J];实用临床医学;2014年03期
4 黄浩哲;李文涛;;动脉自旋标记技术的研究进展[J];中国癌症杂志;2013年11期
5 王建伟;施海彬;刘圣;王敏;鲁珊珊;祖庆泉;;反转恢复时间对动脉自旋标记技术脑灌注成像的影响[J];江苏医药;2012年06期
6 王利;郑罡;赵铁柱;郭超;李林;卢光明;;动脉自旋标记技术在脑部疾病中的临床应用[J];生物医学工程学杂志;2013年01期
7 朱记超;娄明武;张方t,
本文编号:1745402
本文链接:https://www.wllwen.com/yixuelunwen/fangshe/1745402.html