发布时间:2018-10-08 10:04
【摘要】:目的分析VERION数字导航系统测量角膜曲率和散光的可重复性及其与iTrace、Lenstar LS900、手动角膜曲率计检测结果的一致性。方法对62名年龄相关性白内障患者分别用上述四种仪器进行角膜生物测量,记录并分析陡峭轴角膜曲率(steep keratometry,Ks)、平坦轴角膜曲率(flat keratometry,Kf)、散光幅度、散光轴位、矢量参数J0和J45。分析VERION测量的可重复性,并比较VERION与其他三种仪器测量结果的一致性。结果用组内相关系数(intraclass correlation coefficient,ICC)和克隆巴赫系数(Cronbach’s alpha,α)分别对Ks、Kf、散光幅度、散光轴位、J0以及J45做出分析,结果均大于0.9(均为P0.001),提示VERION测量角膜曲率及散光的可重复性极好。VERION测量的Ks、散光幅度均高于iTrace(均为P0.05),其余指标的差异无统计学意义(均为P0.05)。Bland-Altman分析显示J0、J45及散光轴位的95%LOA分别为(-0.31~0.35)D、(-0.25~0.31)D、-13.5°~12.3°。二者测量的散光轴位差小于10°者占总体的77%(48/62),在合并角膜散光大于1D的患者中占91%(42/46)。VERION与Lenstar LS900测量结果仅J45差异有统计学意义(P0.05),其余指标差异无统计学意义(均为P0.05)。Bland-Altman分析发现J0、J45及散光轴位的95%LOA分别为(-0.25~0.31)D、(-0.27~0.36)D、-13.5°~11.0°。二者测量的散光轴位差小于10°者占总体的85%(53/62),在合并角膜散光大于1D的患者中占93%(43/46)。VERION与手动角膜曲率计检测的Kf、散光幅度差异有统计学意义(均为P0.05),其余指标差异无统计学意义(均为P0.05)。Bland-Altman分析显示J0、J45及散光轴位的95%LOA分别为(-0.38~0.35)D、(-0.41~0.42)D、-12.6°~16.4°。二者测量的散光轴位差小于10°者占总体的81%(50/62),在合并角膜散光大于1D的患者中占91%(42/46)。结论VERION在测量角膜曲率及散光方面具有良好的可重复性。其与iTrace、Lenstar LS900和手动角膜曲率计在角膜曲率、散光幅度的测量方面一致性较好,但对散光轴位的测量差别较大。
[Abstract]:Objective to analyze the repeatability of VERION digital navigation system in measuring corneal curvature and astigmatism and its consistency with iTrace,Lenstar LS900, manual keratometer. Methods 62 patients with age-related cataract were measured with the above four instruments. The corneal curvature (steep keratometry,Ks), flat-axis corneal curvature (flat keratometry,Kf), astigmatism amplitude, astigmatism axis, vector parameters J _ 0 and J _ 45 were recorded and analyzed. The repeatability of VERION measurement is analyzed and the consistency between VERION and other three instruments is compared. Results the astigmatism amplitude, astigmatism axis J0 and J45 of Ks,Kf, were analyzed by intra-group correlation coefficient (intraclass correlation coefficient,ICC) and Kronbach coefficient (Cronbach's alpha, 伪), respectively. The results were all greater than 0. 9 (P0. 001), indicating that the Ks, astigmatism amplitude measured by VERION was higher than that of iTrace (P0.05). The other indexes were not significantly different (P0.05). Bland-Altman analysis showed that the 95%LOA of J0 J45 and astigmatism axis were (-0.31) 0.35) D, (-0.250.31 DU -13.5 掳12.3 掳. 77% (48 / 62) of the patients with astigmatism less than 10 掳measured, 91% (42 / 46) of the patients with corneal astigmatism greater than 1D, only J45 (P0.05) compared with Lenstar LS900, but no significant difference was found in other indexes (P0.05) .Bland-Altman score. The 95%LOA of J0 / J45 and astigmatism axis is (-0.25 ~ 0.31) D, (-0.27 ~ 0.36) DU -13.5 掳~ 11.0 掳, respectively. 85% (53 / 62) of the patients with astigmatism less than 10 掳measured, 93% (43 / 46) of the patients with corneal astigmatism greater than 1D, and 93% (43 / 46) of the patients with corneal astigmatism were significantly different from the Kf, astigmatism measured by manual keratometer (P0.05). Statistical significance (P0.05). Bland-Altman analysis showed that the 95%LOA of J0 / J45 and astigmatism axis were (-0.38) 0.35) D, (-0.41 ~ 0.42) DU -12.6 掳and 16.4 掳respectively. The axial difference of astigmatism less than 10 掳accounted for 81% (50 / 62) of the total, and 91% (42 / 46) of the patients with corneal astigmatism greater than 1D. Conclusion VERION has good reproducibility in measuring corneal curvature and astigmatism. It is consistent with iTrace,Lenstar LS900 and manual keratometer in the measurement of corneal curvature and astigmatism amplitude, but the measurement of astigmatism axis is quite different.
【作者单位】: 天津医科大学眼科临床学院天津医科大学眼科医院;
【分类号】:R770.4

【相似文献】

相关期刊论文 前10条

1 洪荣照,吴正秀,王骞,刘晓瑞,叶梅;角膜曲率的分析[J];眼科;2002年04期

2 朱思强;角膜塑型术后角膜曲率的转归[J];眼视光学杂志;2005年02期

3 Langenbucher A;Naumann G.O.H;Seitz B;陈立军;;采用回归模型研究穿透性角膜移植术拆线后角膜曲率及散光的自发性、长期性改变[J];世界核心医学期刊文摘.眼科学分册;2005年12期

4 陈丽萍;赵堪兴;郑曰忠;李丽华;刘菊;;3~15岁儿童角膜曲率调查与分析[J];天津医科大学学报;2005年04期

5 庄云;王薇;魏梅;朱冉;熊维亚;;两种角膜曲率测量方法在临床中的应用[J];眼外伤职业眼病杂志.附眼科手术;2006年04期

6 梁琼,曾怡谋,罗雄伟,黄玲;角膜曲率对准分子激光屈光性角膜切削术手术效果的影响[J];河北医学;2001年06期

7 李新宇;刘磊;袁菁;董洁玉;邹艳;;不同角膜曲率测量方法结果的比较[J];国际眼科杂志;2006年03期

8 刘永琰;周琼;张莉花;;准分子激光原位角膜磨镶术后角膜曲率的变化及意义[J];江西医药;2006年11期

9 许燕玉;范军华;李学喜;;角膜曲率与年龄及性别的相关性分析[J];国际眼科杂志;2009年05期

10 张东升,米伟,,张帆,雷志辉;角膜曲率的全场测量技术[J];实验力学;1995年02期

相关硕士学位论文 前8条

1 钱娜娜;三种仪器测量飞秒激光-LASIK术前术后角膜曲率的研究[D];新乡医学院;2015年

2 董洁玉;角膜屈光手术后角膜曲率计算方法的分析研究[D];华中科技大学;2006年

3 董兴国;高角膜曲率近视患者准分子激光术后长期安全性的观察[D];河北医科大学;2013年

4 谢文渊;IOLMaster测量眼球轴长和角膜曲率与A超和角膜曲率计测量的相关性研究[D];浙江大学;2009年

5 肖静;IOL Master对硅油取出前后眼轴及角膜曲率测量的临床研究[D];大连医科大学;2010年

6 潘虹;Pentacam在青少年屈光要素测量中的应用[D];山东大学;2008年

7 魏超;Lenstar LS 900 与IOL-Master测量屈光不正儿童眼轴长度和角膜曲率的比较[D];山东大学;2011年

8 丁锦;Lenstar及传统方法测量lasik术后眼球相关生物参数的比较分析[D];安徽医科大学;2014年



本文编号:2256365

资料下载
论文发表

本文链接:https://www.wllwen.com/yixuelunwen/wuguanyixuelunwen/2256365.html


Copyright(c)文论论文网All Rights Reserved | 网站地图 |

版权申明:资料由用户ee146***提供,本站仅收录摘要或目录,作者需要删除请E-mail邮箱bigeng88@qq.com