白内障术后人工晶体倾斜与偏心的研究
发布时间:2018-12-13 06:36
【摘要】: 目的:观察分析我院门诊诊断慢性闭角型青光眼30例(41只眼)的临床特点,分析总结慢性闭角型青光眼的临床特征、视神经损伤机理、视神经纤维层(RNFL)平均厚度与视野缺损的相关性。 方法:对30例慢性闭角型青光眼患者41只眼进行相干断层扫描(OCT)及视野检查,对其RNFL平均厚度和视野进行测量,使用SPSS 11.5统计软件,采用相关分析方法对RNFL平均厚度与视野缺损进行统计学处理。 结果:通过对41只眼的统计分析,结果显示:RNFL平均厚度与平均缺损(MD)、平均敏感度(MS)相关(r=-0.623,p0.01;r=0.568,p0.01)。 结论:海德堡Spectralis OCT型扫描仪RNFL程序在慢性闭角型青光眼的诊断上与瑞士OCTOPUS 101视野计G2程序高度相关。
[Abstract]:Objective: to observe and analyze the clinical characteristics of 30 cases (41 eyes) of chronic angle-closure glaucoma diagnosed in outpatient clinic of our hospital, and to analyze and summarize the clinical characteristics of chronic angle closure glaucoma and the mechanism of optic nerve injury. Correlation between (RNFL) mean thickness of optic nerve fiber layer and visual field defect. Methods: coherence tomography (OCT) and visual field examination were performed in 41 eyes of 30 patients with chronic angle closure glaucoma. The mean thickness and visual field of RNFL were measured by SPSS 11.5 software. Correlation analysis was used to analyze the mean thickness of RNFL and visual field defect. Results: the average thickness of RNFL was correlated with the average sensitivity of (MD), in 41 eyes (r = 0.623, p 0.01). The results showed that the mean thickness of RNFL was significantly correlated with the average sensitivity of (MD), (r = 0.623, p 0.01n = 0.568 / p 0.01). Conclusion: the RNFL program of Heidelberg Spectralis OCT scanner is highly correlated with OCTOPUS 101 visual field G 2 program in the diagnosis of chronic angle closure glaucoma.
【学位授予单位】:河北医科大学
【学位级别】:硕士
【学位授予年份】:2010
【分类号】:R779.66
本文编号:2376085
[Abstract]:Objective: to observe and analyze the clinical characteristics of 30 cases (41 eyes) of chronic angle-closure glaucoma diagnosed in outpatient clinic of our hospital, and to analyze and summarize the clinical characteristics of chronic angle closure glaucoma and the mechanism of optic nerve injury. Correlation between (RNFL) mean thickness of optic nerve fiber layer and visual field defect. Methods: coherence tomography (OCT) and visual field examination were performed in 41 eyes of 30 patients with chronic angle closure glaucoma. The mean thickness and visual field of RNFL were measured by SPSS 11.5 software. Correlation analysis was used to analyze the mean thickness of RNFL and visual field defect. Results: the average thickness of RNFL was correlated with the average sensitivity of (MD), in 41 eyes (r = 0.623, p 0.01). The results showed that the mean thickness of RNFL was significantly correlated with the average sensitivity of (MD), (r = 0.623, p 0.01n = 0.568 / p 0.01). Conclusion: the RNFL program of Heidelberg Spectralis OCT scanner is highly correlated with OCTOPUS 101 visual field G 2 program in the diagnosis of chronic angle closure glaucoma.
【学位授予单位】:河北医科大学
【学位级别】:硕士
【学位授予年份】:2010
【分类号】:R779.66
【参考文献】
相关期刊论文 前10条
1 杨朝忠;林振德;谢楚芳;;人工晶体免疫学研究的探讨[J];国外医学.眼科学分册;1987年05期
2 王荣光;连续环形撕囊术与白内障囊外摘出术[J];国外医学.眼科学分册;1994年01期
3 王杨;王肇圻;郭欢庆;全薇;;人眼的高级像差对视功能的影响[J];光学学报;2005年11期
4 朱海丰;方志良;刘永基;;人工晶体倾斜与偏心对人眼视功能的影响[J];光子学报;2008年01期
5 饶惠英,王丽天;人眼晶状体悬韧带的张力测定[J];临床眼科杂志;2002年03期
6 黄爱萍;;300例白内障连续环形撕囊分析[J];实用防盲技术;2009年01期
7 王琳,王兴淼;白内障现代囊外摘出术中后囊膜破裂[J];眼科新进展;2003年02期
8 姚克;;非球面人工晶状体会全面取代球面人工晶状体吗?[J];眼科;2006年01期
9 江洁;剥脱综合征与白内障手术[J];眼外伤职业眼病杂志.附眼科手术;2002年04期
10 郭海科,张洪洋,金海鹰;环形撕囊及人工晶状体因素对后囊浑浊的影响[J];眼外伤职业眼病杂志.附眼科手术;2004年05期