当前位置:主页 > 医学论文 > 预防医学论文 >

XAD-7吸附-毛细管柱气相色谱法测定工作场所空气中乙二醇

发布时间:2018-06-29 10:28

  本文选题:乙二醇 + 离子交换树脂 ; 参考:《环境监测管理与技术》2016年06期


【摘要】:采用离子交换树脂XAD-7吸附-毛细管柱气相色谱法测定工作场所空气中乙二醇,结果表明,该方法在0 mg/L~1 116 mg/L范围内线性良好,方法检出限为0.88 mg/L,当采样体积为7.5 L时,最低检出质量浓度为0.11 mg/m3。乙二醇标准溶液测定结果的RSD为1.3%,空白加标回收率为80.1%~107%,方法的采集效率为98.0%。
[Abstract]:The determination of ethylene glycol in workplace air by ion exchange resin XAD-7 adsorption-capillary gas chromatography shows that the method has a good linearity in the range of 0 mg / L ~ (-1 116) mg / L, and the detection limit is 0.88 mg / L, and when the sampling volume is 7.5 L, the detection limit of the method is 0.88 mg 路L ~ (-1). The lowest detectable mass concentration was 0.11 mg / m ~ (3). The RSD of the determination of ethylene glycol standard solution was 1.3 and the recovery rate of blank standard solution was 80.1 and 107.The collection efficiency of the method was 98.0.
【作者单位】: 苏州市环境监测中心站;苏州科技大学;苏州外国语学校;
【分类号】:O657.7+1


本文编号:2081814