小型化Spreeta SPR免疫传感器在大肠杆菌O157:H7检测中的研究
[Abstract]:E. coli 0157:H7 (E. coli 0157:H7, as one of the most harmful foodborne pathogens, has the possibility of epidemic outbreak and the severity of infection in China. Because of the disadvantages of complicated operation, laborious operation and time consuming in the traditional detection methods, it is urgent to develop a fast and accurate detection method. In this paper, many new detection techniques, including biosensors, have been investigated. According to the advantage of Spreeta SPR sensor, the Spreeta SPR sensor and cell lysis method were taken as the main research means and content, the detection of O157:H7 in E. coli was realized, and it was discussed and studied deeply. The main research contents and results are as follows: (1) the performance of Spreeta SPR sensor is evaluated with different concentrations of glucose solution. The correlation coefficient between glucose concentration and refractive index is close to 1, and the baseline is restored after rinsing with deionized water. The sensor has good performance. (2) the repeatability of the response results of avidin and biotinylated antibody showed that the sensor had high reproducibility, which provided a theoretical basis for the detection of Escherichia coli O157:H7 by Spreeta SPR immunosensor. The detection limit was 3 脳 10 ~ 6 cfu mL-1,. Basically meet the test needs. (3) comparing the sensitivity of BIACORE SPR immunosensor, the detection limit of direct detection of Escherichia coli O157:H7 is 3 脳 10 ~ 5 cfu mL-1,. The sensitivity of, Spreeta SPR immunosensor is comparable to that of (ELISA) by enzyme linked immunosorbent assay (Elisa). The sensitivity of, Spreeta SPR immunosensor needs to be improved. (4) the detection limit was decreased to 3 脳 10 ~ 4 cfu mL-1, after ultrasonic treatment with Spreeta SPR immunosensor and cell lysis technique. The correlation coefficient was 0.98. The results show that the cell lysis technique can effectively reduce the detection limit of the sensor. (5) Escherichia coli DH 5 伪 and Listeria were used to test the specificity of the biosensor to Escherichia coli 0157:H7. The results showed that the specificity of the biosensor to the target bacteria was good, and the adsorption of the validation bacteria was very small.
【学位授予单位】:浙江大学
【学位级别】:硕士
【学位授予年份】:2012
【分类号】:R155.5
【参考文献】
相关期刊论文 前10条
1 王锋;樊先平;王民权;;光学生物传感器的研究进展[J];材料导报;2004年07期
2 张文浩;郑先哲;初国超;;应用SPR生物传感器检测酸菜发酵液中大肠杆菌[J];东北农业大学学报;2010年06期
3 曹振新,粱大开,郭明江;光纤表面等离子体波传感器的温度特性的研究[J];光谱学与光谱分析;2003年01期
4 曾捷;梁大开;曾振武;杜燕;;基于SPR光谱分析的液体折射率测量研究[J];光谱学与光谱分析;2006年04期
5 唐倩倩;王剑平;盖玲;叶尊忠;应义斌;;ATP生物发光法检测E. coliO157∶H7的研究[J];光谱学与光谱分析;2009年02期
6 丁红雷,毛旭虎,邹全明,王豪举;肠出血性大肠杆菌O157:H7的分子生物学检测方法研究进展[J];国外医学.临床生物化学与检验学分册;2005年08期
7 唐晓艳;张洪友;;SPR生物传感器及其应用进展[J];中国畜牧兽医;2006年04期
8 葛晶,殷涌光,王凯;使用SPR生物传感器快速检测大肠杆菌E.Coli 0157∶H7[J];吉林大学学报(工学版);2005年02期
9 王燕琴;朱建勇;;肠出血性大肠杆菌O157:H7检测方法研究进展[J];内蒙古农业科技;2010年03期
10 徐尚荣;;大肠杆菌O157∶H7的生物学特性[J];青海畜牧兽医杂志;2008年04期
相关硕士学位论文 前2条
1 孙洋;肠出血性大肠杆菌0157多重PCR检测及其stx基因缺失突变株的研究[D];中国人民解放军军需大学;2002年
2 陈思;肠出血性大肠杆菌O157:H7的PCR与免疫学检测技术的研究[D];中国农业大学;2005年
,本文编号:2411753
本文链接:https://www.wllwen.com/yixuelunwen/yufangyixuelunwen/2411753.html