离子色谱-直接电导法检测盐酸二甲双胍药物中二甲胺的残留
发布时间:2018-04-01 01:38
本文选题:离子色谱 切入点:直接电导法 出处:《药物分析杂志》2017年11期
【摘要】:目的:建立离子色谱-直接电导法测定盐酸二甲双胍药物中二甲胺残留的方法。方法:盐酸二甲双胍药物用水溶解后直接进样,采用20 mmol·L~(-1)甲磺酸水溶液为淋洗液,以Dionex Ionpac CS12A(4 mm×250 mm)色谱柱进行分离,流速为1.0 m L·min~(-1),CSRS 500-4 mm阳离子抑制器和电导检测器抑制并直接检测,抑制电流60 m A,柱温30℃,进样体积25μL。结果:二甲胺在0.1~10.0μg·m L~(-1)范围内线性关系良好(r=0.999 4),方法的检测限为0.032 8μg·m L~(-1)(S/N=3),方法的定量下限为0.12μg·m L~(-1)(S/N=10),平均回收率为97.6%~99.5%,RSD均不超过3%。结论:该方法操作简单、灵敏度高、重现性好,可用于盐酸二甲双胍药物中二甲胺残留的检测。
[Abstract]:Objective: to establish an ion chromatography-direct conductance method for the determination of metformin hydrochloride residues in metformin hydrochloride. A Dionex Ionpac CS12A(4 mm 脳 250mm column was used to separate the column. The flow rate was 1.0 mL / min ~ (-1) and CSRS 500-4 mm cationic suppressor and conductance detector were suppressed and detected directly. The suppression current was 60 Ma and the column temperature was 30 鈩,