穿戴式单导联心电监测系统及检测位置综合研究
本文选题:心电信号 + 单导联 ; 参考:《浙江大学》2017年硕士论文
【摘要】:随着心血管疾病患病人数的迅速增长,实时监测心脏健康的需求也与日俱增。而传统心电监护设备因导联数众多、缺乏便携性,无法满足患者需求,因此研究更智能、更便捷的可穿戴心电监护设备十分必要。目前,单导联可穿戴心电监测设备因为导联数少、体积小、便携舒适等特点,在人体心电信号的监测领域逐渐成为热点。然而对于其检测位置、该位置单导联心电信号可靠性以及医疗辅助诊断价值还没有明确的说明。本论文设计了一套穿戴式4电极方形心电监测系统,进行多通道单导联心电信号检测;相应地提出了一种分层网格分布测试评估方法,进行心电信号的采集和评估,最终确定了最佳的单导联心电信号检测位置。此外,本文自制了一套单导联心电监测系统,对最佳测量位置处的单导联心电信号进行了临床研究。结果表明,实验确定的最佳测量位置处的心电信号特征明显。临床试验结果也表明,该位置处的心电信号包含的心率、QRS波群宽度以及P波宽度等特征与标准心电监护仪基本一致。因此本文确定的最佳测量位置处的单导联心电信号具备一定的医疗诊断价值。
[Abstract]:With the rapid increase in the number of cardiovascular diseases, the need for real-time monitoring of heart health is increasing. The traditional ECG monitoring equipment is lack of portability and can not meet the needs of patients, so it is necessary to study more intelligent and convenient wearable ECG monitoring equipment. At present, single lead wearable ECG monitoring equipment has become a hot spot in the field of human ECG monitoring because of its small number of leads, small volume, portable comfort and so on. However, the reliability of single lead ECG signal and the value of medical auxiliary diagnosis are not clearly explained. In this paper, a wearable four-electrode square ECG monitoring system is designed to detect multi-channel single-lead ECG signals, and a hierarchical grid distribution testing and evaluation method is proposed to collect and evaluate ECG signals. Finally, the best detection position of single lead ECG signal is determined. In addition, a set of single lead ECG monitoring system is made in this paper, and the single lead ECG signal at the best measuring position is studied clinically. The results show that the electrocardiogram (ECG) characteristics at the best measuring position determined by the experiment are obvious. The clinical results also show that the ECG signals at this position contain the characteristics of heart rate, QRS wave group width and P wave width, which are basically consistent with the standard ECG monitor. Therefore, the single-lead ECG at the best measuring position is valuable for medical diagnosis.
【学位授予单位】:浙江大学
【学位级别】:硕士
【学位授予年份】:2017
【分类号】:R540.4;TP274
【参考文献】
相关期刊论文 前7条
1 陈伟伟;高润霖;刘力生;朱曼璐;王文;王拥军;吴兆苏;李惠君;郑哲;蒋立新;胡盛寿;;《中国心血管病报告2014》概要[J];中国循环杂志;2015年07期
2 杨向林;严洪;许志;任兆瑞;宋晋忠;姚宇华;李延军;;基于Hilbert-Huang变换的ECG消噪[J];电子学报;2011年04期
3 李桥;Roger G Mark;Gari D Clifford ;俞梦孙;;基于信号质量评估和卡尔曼滤波的心率估计算法[J];中国医学物理学杂志;2007年06期
4 郝红伟;马伯志;李路明;曹洋;;基于双电极的心电测量方法及仪器[J];航天医学与医学工程;2007年05期
5 李小燕,王涛,冯焕清,詹长安;基于小波变换的自适应滤波器消除ECG中基线漂移[J];中国科学技术大学学报;2000年04期
6 丁哨卫,张作生,冯焕清,彭虎;基于自适应小波变换的QRS波检测算法[J];中国科学技术大学学报;1998年05期
7 杨丰,余英林;小波变换在心电信号滤波处理中的应用研究[J];生物医学工程学杂志;1997年04期
相关硕士学位论文 前5条
1 李珂;穿戴式心电监护设备的低功耗技术研究[D];浙江大学;2015年
2 陈方剑;标准12导联心电信号重建方法研究[D];浙江大学;2015年
3 张煜;可穿戴动态心电监护系统与心电信号处理方法研究[D];电子科技大学;2014年
4 牛传莉;心电信号预处理和波形检测算法的研究[D];北京交通大学;2009年
5 孙振华;腕带式多参数健康监护系统的研究[D];哈尔滨工业大学;2007年