437例兼容磁共振心脏植入装置临床应用的回顾性分析
[Abstract]:Objective to investigate the clinical application and safety of magnetic resonance (MRI) compatible cardiac implants (CIED). Methods from June 2014 to November 2016, 437 patients with compatible MRI cardiac implants were successfully implanted in Department of Cardiovascular Medicine, second affiliated Hospital of Zhejiang University. The basic clinical data of the patients were collected, CIED information was implanted, and the pacing lead parameters, MRI examination and complications of 48 hours, 1 ~ 3 and 6 months postoperatively were followed up. Results there were 437 patients, 246 males and 191 females, with an average age of 69.1 卤12.9 years. There were 2 patients with pacemaker replacement, 435 patients with first CIED implantation, 15 patients with implantable cardioverter defibrillator (ICD),) and 2 patients with cardiac resynchronization therapy pacemaker / defibrillator (CRT-P/D). 2 cases (0.45%) were transposed and 24 cases (5.49%) underwent MRI examination. No related adverse events were observed, and the traverse parameters remained stable before and after MRI examination. 48 hours after operation, the perception of right atrium and right ventricle (3.5 卤1.9mV/13.2 卤5.3mV) was significantly higher than that during operation (3.1 卤1.5mV/10.8 卤6.3mV). The impedance of right atrial and right ventricular pacing conductors (517 卤85 惟 / 602 卤105 惟) at 48 hours after operation was significantly lower than that during operation (624 卤149 惟 / 740 卤165 惟) (p0.05). The threshold of right atrial pacing (0.79 卤0.27V) was lower than that of intraoperative pacing (1.03 卤0.68) 48 hours after operation, but there was no significant difference (p0.05). There were no significant changes in pacing lead parameters 48 hours after operation and 1 ~ 6 months after operation. Conclusion compatible magnetic resonance CIED is safe for pacing, suitable for MRI examination under specific conditions, and stable in working state of pacemakers in short term follow-up.
【学位授予单位】:浙江大学
【学位级别】:硕士
【学位授予年份】:2017
【分类号】:R541
【相似文献】
相关期刊论文 前10条
1 杨杰孚,Anne Powell,Michael Davi;经下腔静脉途径拔除起搏导线的初步体会[J];中华心律失常学杂志;2000年01期
2 杜修海,张明旭,张卫泽,王艳春,张爱君;介绍一种小儿起搏导线处理的新方法[J];中华心律失常学杂志;2000年04期
3 刘峰,林祖近;血管内反推力牵引法拔除感染性心内膜起搏导线(附二例报告)[J];温州医学院学报;2001年06期
4 冯振勤;谷惠敏;于宗良;顾明;赵志强;;静脉造影在永久性心脏起搏导线置入中的应用价值探讨[J];交通医学;2007年03期
5 周滔;周胜华;祁述善;沈向前;刘启明;李旭平;;主动固定起搏导线导致心脏穿孔3例及文献复习[J];临床心血管病杂志;2008年08期
6 陈小芳;李乐之;;主动固定起搏导线导致心脏穿孔的护理[J];当代护士(专科版);2009年11期
7 张学禄;全国心脏起搏导线断裂并发症高级研讨会在京召开[J];中国医疗器械信息;1996年05期
8 郑向青,李正恭,梅霞;起搏导线初装与更换时电参数对照[J];重庆医学;1998年04期
9 杜修海;秦勉;张明旭;曹世平;胡静泠;;拔除起搏导线残端滑入心内一例[J];中华心律失常学杂志;1998年04期
10 冯义柏,王祥,贺立群,方宏;永久起搏导线断裂原因初探[J];临床心电学杂志;1999年03期
相关会议论文 前4条
1 葛世俊;;起搏导线的选择[A];2006年浙江省心电生理与起搏学术年会论文汇编[C];2006年
2 沙来买提沙力;徐勋龙;刘恩焘;贾林;宿燕岗;葛均波;;不同起搏导线植入术中的损伤电流特征[A];中华医学会心电生理和起搏分会第十次全国学术年会会议汇编[C];2012年
3 魏富贵;;1例经胸行左心室心外膜行起搏导线植入术的护理[A];第三届江浙沪三地老年医学高峰论坛暨2012年浙江省老年医学学术年会论文集[C];2012年
4 唐疾飞;;Chiari 网导致起搏导线缠绕的处理[A];2004年浙江省心血管病学学术年会论文汇编[C];2004年
相关硕士学位论文 前4条
1 胡芬;永存左上腔静豚起搏导线植入方法探讨[D];浙江大学;2016年
2 焉晓蕾;左心室四极与传统起搏导线起搏参数比较及应用[D];大连医科大学;2016年
3 张栋铭;437例兼容磁共振心脏植入装置临床应用的回顾性分析[D];浙江大学;2017年
4 王鹏;应用实时三维超声观察心内起搏导线的研究[D];昆明医学院;2009年