iDose~4迭代重建技术和滤波反投影技术在冠状动脉CT成像中的应用
[Abstract]:Objective: to investigate the feasibility of using iDose4 iterative technique to improve image quality and reduce radiation dose in coronary artery CT imaging, compared with conventional filtering backprojection technique (FBP). Methods: 60 patients undergoing 256-slice spiral CT coronary angiography were randomly divided into two groups, 30 patients in each group. One group uses 120kV voltage and uses filter backprojection technique (FBP-120kV group) and iDose4 iterative technique (iDose4-120kV group), the other group uses 100kV tube voltage and iDose4 iterative technique (iDose4-100kV group). The image quality of FBP-120kV group was compared with that of iDose4-120kV group and iDose4-100kV group, and the radiation doses of FBP-120kV group and iDose4-100kV group were compared. Results: in subjective evaluation of image quality, the average image quality score of FBP-120kV group was (3.29 卤0.61) and that of iDose 4-120kV group was (3.43 卤0.51), and there was no significant difference between the two groups (t = 1.47, P ~ (0.17), and the mean value of image quality score of iDose 4-100 kV group was (3.21 卤0.43). Compared with FBP-120kV group, there was no significant difference (t0. 58). The ratio of signal noise to (SNR) and contrast noise ratio to (CNR) in iDose 4-120 kV group were higher than those in FBP-120kV group (P0.05), SNR and CNR in iDose 4-100 kV group were lower than those in FBP-120kV group, but the difference was not statistically significant (P0.05). The effective dose (ED) of iDose 4-100 kV group was significantly lower than that of FBP-120kV group (P0. 001). Conclusion: compared with filtered backprojection technique, iDose4 iterative reconstruction technique can improve image quality in coronary artery CT imaging, and the dose of radiation can be reduced by properly reducing the tube voltage under the condition that the image quality is not changed.
【作者单位】: 吉林大学第二医院放射线科;
【基金】:吉林省科技厅自然科学基金资助课题(20130413006GH)
【分类号】:R816.2
【相似文献】
相关期刊论文 前10条
1 叶华俊,刘华锋;正电子发射断层成像重建算法评述[J];生物医学工程学杂志;2002年03期
2 罗戎蕾,汪元美,高欣;小波理论在CT图像滤波反投影重建算法中的应用[J];中国中西医结合影像学杂志;2004年01期
3 王志伟;于强;舒春梅;谭润初;贺奇才;;计算机模拟CT滤波反投影重建的方法[J];中国医学物理学杂志;2010年02期
4 孙丰荣,刘积仁;CT滤波反投影图像重建算法的反投影计算量问题[J];中国生物医学工程学报;2004年06期
5 黄海波;黄桂雄;林莹;管俊;曾嵩;;滤波反投影的冠状动脉CTA低剂量优化方案初探[J];中华临床医师杂志(电子版);2014年12期
6 范毅;卢虹冰;郝重阳;;扇形模式下SPECT图像重建算法之比较研究[J];第四军医大学学报;2007年10期
7 M.J. Willemink;P.A. de Jong;T. Leiner;L.M. de Heer;R.A.J. Nievelstein;R.P.J. Budde;李鹏;;CT迭代重建技术第一部分:技术原理[J];国际医学放射学杂志;2013年04期
8 A.Kurata;A.Dharampal;A.Dedic;P.J.de Feyter;G.P.Krestin;M.L.Dijkshoorn;袁涛;;迭代重建对冠状动脉CTA钙化积分的影响[J];国际医学放射学杂志;2014年01期
9 陈晓艳;张静;;采用阈值修正法改善电阻抗图像质量[J];中国生物医学工程学报;2011年04期
10 张聪哲;李晓苇;杨昆;;扇束等角型CT与等距型CT的比较研究[J];CT理论与应用研究;2013年02期
相关会议论文 前2条
1 柯丽;杜强;王旭;;基于滤波反投影的磁感应图像重建算法研究[A];第七届全国信息获取与处理学术会议论文集[C];2009年
2 高伟雁;孙毅刚;;滤波反投影算法在CT检测中的应用[A];计算机技术与应用进展·2007——全国第18届计算机技术与应用(CACIS)学术会议论文集[C];2007年
相关博士学位论文 前1条
1 王云霄;医疗CT运动伪像研究[D];吉林大学;2007年
相关硕士学位论文 前6条
1 郑世伟;一种基于Kintex-7开发板的CBCT图像重建加速系统的研究[D];哈尔滨工业大学;2014年
2 杨艳芳;基于一种新的扫描方式的滤波反投影算法[D];北京交通大学;2009年
3 翟静;三维锥束CT中滤波反投影算法的研究[D];中北大学;2008年
4 张斌;滤波反投影图像重建算法中插值和滤波器的研究[D];中北大学;2009年
5 范慧峗;CT图像滤波反投影重建算法的研究[D];西北工业大学;2007年
6 周宇;统计重建在X线CT中的应用研究[D];天津大学;2006年
,本文编号:2169928
本文链接:https://www.wllwen.com/yixuelunwen/xxg/2169928.html